Programmer Guide/SPU Reference/AVR: Difference between revisions
From STX Wiki
Jump to navigationJump to search
No edit summary |
No edit summary |
||
| Line 3: | Line 3: | ||
==<code>[SPU AVR <var>X TYP T RS</var> OUT <var>Y</var>]</code>== | ==<code>[SPU AVR <var>X TYP T RS</var> OUT <var>Y</var>]</code>== | ||
{|class="einrahmen" | {|class="einrahmen" | ||
!input !!description !!data type !!value type!!default | !input !!description !!data type !!value type!!default value | ||
|- | |- | ||
|<var>X</var>||data to be averaged ||number, vector, matrix ||variable | |<var>X</var>||data to be averaged ||number, vector, matrix ||variable | ||
Revision as of 12:13, 6 May 2011
Average input X over evaluation cycles.
[SPU AVR X TYP T RS OUT Y]
| input | description | data type | value type | default value |
|---|---|---|---|---|
| X | data to be averaged | number, vector, matrix | variable | |
| TYP | averaging method | number (int.), string | constant | |
| T | averaging parameter, depends on method | number or n.c. | TYP=2→variable TYP≠2→constant | |
| RS | reset flag | number or n.c. | variable | |
| output | description | data type | value type | comment |
| Y | averaged input data | same type as X | variable |
- Description
The averaging algorithm is defined by the inputs TYP and T. The atom averages the elements X[i,j]t over evaluation cycles t (i=row index, j=column index, t=cycle counter) and stores the averaged value in the element Y[i,j]t.
The cycle counter t is initialized with 0 and incremented by 1 after each evaluation cycle. The cycle counter is reset, if the input RS is set to a value greater than 0. The input RS is checked each time the SPU is started.
- infinite average
- TYP=
0orlinear - T=
0 - running average
- TYP=
0orlinear - T>
0; T is the (integer) number of averaging cycles - exponential average
- TYP=
1orexponential 0<T<1; T is the averaging factor- minimum
- TYP=
2orminimum - T is not used
- maximum
- TYP=
3ormaximum - T is not used
- See also
<SP-atoms>