Programmer Guide/SPU Reference/LIMITER: Difference between revisions

From STX Wiki
Jump to navigationJump to search
(initial import)
 
 
(25 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{DISPLAYTITLE:{{SUBPAGENAME}}}}
{{DISPLAYTITLE:{{SUBPAGENAME}}}}
====LIMITER - amplitude limiter (non-linear)====
Apply a non-linear limiter function to a signal.
 
==<code>[SPU LIMITER <var>X TYPE MAX LIM</var> OUT <var>Y Q</var>]</code>==
The <code>LIMITER</code> spatom applies a non-linear magnitude weighting to the signal. The limiter function is only applied if the absolute value of the signal magnitude is higher than the specified limiter start magnitude <var>LIM</var>. For the limiter function, the following algorithm is used:
{|class="einrahmen"
 
!input !!description !!data type !!value type!!default value
[[File:1240.png]]
|-
 
|<var>X</var>||input signal||number, vector ||variable
with:
|-
 
|<var>TYPE</var>||limiter function<BR>(<code>RECTANGLE, ATAN, EXPONENTIAL</code>)||number (int.), string||constant ||<code>0</code> (= <code>RECTANGLE</code>)
{|
|-
|<var>MAX</var>||maximum value; 0 &lt; <var>MAX</var>||number||constant ||<code>1</code>
|-
|<var>LIM</var>||limiter start value; 0 &lt; <var>LIM</var> &le; <var>MAX</var>||number||constant ||<code>1</code>
|-
|-
|x, y
!output !!description !!data type !!value type!!comment
|input and output signal sample
|-
|-
|LIM, <var>MAX</var>
|<var>Y</var>||limited signal||same type as <var>A</var>||variable
|limiter start amplitude and maximum signal amplitude
|-
|-
|f()
|<var>Q</var>||relative number of limited samples||number||variable
|limiter function selected by input TYPE
|}
|}
 
;Description:
Table: Limiter functions{|
This SP-atom applies a non-linear magnitude weighting (= limiter function) to the signal. The limiter function is only applied if the absolute value of the signal magnitude is higher than the specified limiter start magnitude <var>LIM</var>. For the limiter function, the following algorithm is used:
|-
:<math>y_i = \begin{cases}
|The value of TYPE
x_i  & \mbox{ if }|x_i| \leqslant LIM \\
|The limiter function f(z)
sign(x_i).f \left ( \frac{|x_i|}{MAX} \right ) & \mbox{ otherwise}
\end{cases}
</math>
The absolute magitude of the limited signal is always lower than <var>MAX</var>. The limiter function is selected by the input <var>TYPE</var>.
:{|class="einrahmen"
!<var>TYPE</var> !!limiter function ''f''(''z''<sub>i</sub>)
|-
|-
|0 or RECTANGLE
|<code>0</code> or <code>RECTANGLE</code>
|[[File:1241.png]] ('cut<nowiki>-</nowiki>off')
|<math>k\!</math>
|-
|-
|1 or ATAN
|<code>1</code> or <code>ATAN</code>
|[[File:1242.png]]
|<math>k+(1-k) \cdot \frac{2}{\pi} \cdot atan\left ( \frac{z-k}{1-k} \cdot \frac{\pi}{2} \right )</math>
|-
|-
|2 or EXPONENTIAL
|<code>2</code> or <code>EXPONENTIAL</code>
|[[File:1243.png]]
|<math>1-(1-k) \cdot e^{-\frac{z-k}{1-k}}</math>
|}
|}
:with: <math>z_i = \frac{|x_i|}{MAX}, k = \frac{LIM}{MAX}</math>


with:
[[File:1244.png]]
The output Q is set to the relative number of processed samples:
<var>Q</var> = number of changed samples / number of processed samples
=====Usage:=====
<code>LIMITER <var>X TYPE MAX LIM</var></code>
=====Inputs:=====
;<var>X</var>
:The signal vector or sample.
;<var>TYPE</var>
:The type of limiter function (see table above).
;<var>MAX</var>
:The maximum magnitude (full attenuation).
;<var>LIM</var>
:The limiter start magnitude. This value must be less than <var>MAX</var>.
=====Outputs:=====
;<var>Y</var>
:The limited signal (the same type as <var>X</var>).


;<var>Q</var>
The output <var>Q</var> is set to the relative number of limited (changed) samples.
:<math>Q = \frac{changedSamples}{processedSamples}</math>


:The relative number of limited (changed) samples.
;See also:
<[[../#Signal Processing Atoms|SP-atoms]]>
<!-- AN, 2.5.2011 -->

Latest revision as of 11:54, 9 May 2011

Apply a non-linear limiter function to a signal.

[SPU LIMITER X TYPE MAX LIM OUT Y Q]

input description data type value type default value
X input signal number, vector variable
TYPE limiter function
(RECTANGLE, ATAN, EXPONENTIAL)
number (int.), string constant 0 (= RECTANGLE)
MAX maximum value; 0 < MAX number constant 1
LIM limiter start value; 0 < LIMMAX number constant 1
output description data type value type comment
Y limited signal same type as A variable
Q relative number of limited samples number variable
Description

This SP-atom applies a non-linear magnitude weighting (= limiter function) to the signal. The limiter function is only applied if the absolute value of the signal magnitude is higher than the specified limiter start magnitude LIM. For the limiter function, the following algorithm is used:

{\displaystyle y_{i}={\begin{cases}x_{i}&{\mbox{ if }}|x_{i}|\leqslant LIM\\sign(x_{i}).f\left({\frac {|x_{i}|}{MAX}}\right)&{\mbox{ otherwise}}\end{cases}}}

The absolute magitude of the limited signal is always lower than MAX. The limiter function is selected by the input TYPE.

TYPE limiter function f(zi)
0 or RECTANGLE {\displaystyle k\!}
1 or ATAN {\displaystyle k+(1-k)\cdot {\frac {2}{\pi }}\cdot atan\left({\frac {z-k}{1-k}}\cdot {\frac {\pi }{2}}\right)}
2 or EXPONENTIAL {\displaystyle 1-(1-k)\cdot e^{-{\frac {z-k}{1-k}}}}
with: {\displaystyle z_{i}={\frac {|x_{i}|}{MAX}},k={\frac {LIM}{MAX}}}


The output Q is set to the relative number of limited (changed) samples.

{\displaystyle Q={\frac {changedSamples}{processedSamples}}}
See also

<SP-atoms>

Navigation menu

Personal tools