Programmer Guide/General Descriptions/APar: Difference between revisions
(initial import) |
m (1 revision: Initial import) |
(No difference)
|
Revision as of 17:31, 18 November 2010
APar
The APar
element contains parameters calculated for a specific audio segment. An APar
must be the child of an ASeg
element. The APar
element has the following attributes:
type
- the type of method. The following types exist:
F0 - Fundamental Frequency RMS - Signal Energy Phase - Phase Spectrum ASpec - Amplitude Spectrum Fof - Formant Frequencies Cep - Cepstrum LAT - Log attack time CLPC - LPC coefficient TFA - Amplitude Spectrogram TFP - Phase Spectrogram
method
- the method. The following methods exist:
FO - Formants RMSB - Frequency Band Energy RMS - Signal Energy (RMS) F0A - Fundamental Frequency (SIFT) F0B - Fundamental Frequency (autocorr.) F0H - Fundamental Frequency (harmonic grid) ALPHA - LPC - Error Energy IRRSP - Irrelevance Amplitude Spectrum IRRTH - Irrelevance Threshhold FFT - FFT Amplitude Spectrum FFTP - FFT Phase Spectrum CEPST - Cepstrum Smoothed Spectrum LOFAR - Spectrum - Cepstrum WAVE - Wavelet Amplitude Spectrum WAVEP - Wavelet Phase Spectrum STFT - FFT Amplitude Spectrogram STFTP - FFT Phase Spectrogram STWT - Wavelet Amplitude Spectrogram STWTP - Wavelet Phase Spectrogram LPC - LPC Smoothed Spectrum LPAI - LPC Inverse Filter Coefficients LPRC - LPC Reflection Coefficients LPAR - LPC Area Coefficients
nx
- the number of x axis
ny
- the number of y data vectors
CH
- the channel this parameter was calculated for.
lfrm
- the frame length in milliseconds
sfrm
- the frame shift in milliseconds
nfrm
- the number of frames
date
- the date the parameter was saved
time
- the time the parameter was saved