| Line 37: | Line 37: | ||
:;<var>TYPE</var>=<code>2</code> or <code>RMS</code>: | :;<var>TYPE</var>=<code>2</code> or <code>RMS</code>: | ||
::<math>r_t = \frac{(v_{t-1}.(T-1)+x^2)}{T}</math> | ::<math>r_t = \frac{(v_{t-1}.(T-1)+x^2)}{T}</math> | ||
::<math>v_t = \sqrt | ::<math>v_t = \sqrt{2.r_t}</math> | ||
The computed value ''v'' is converted to the selected <var>UNIT</var> and stored in the output <var>Y</var>. | The computed value ''v'' is converted to the selected <var>UNIT</var> and stored in the output <var>Y</var>. | ||
Revision as of 09:33, 9 May 2011
Level meter (PPM). This atom is used for the level display in the recorder application.
[SPU PPM X TYPE T UNIT REF SIZE OUT Y M P]
| input | description | data type | value type | default value |
|---|---|---|---|---|
| X | input signal | number, vector | variable | |
| TYPE | measurement method ( HOLD, EXPONENTIAL, RMS) |
number (int.), string | constant | 0 (= HOLD)
|
| T | measurement time constant in samples | number | constant | 100
|
| UNIT | output value and unit ( VALUE, SQUARE, RATIO, DB) |
number (int.), string | constant | 0 (=VALUE)
|
| REF | reference value, used for UNIT values RATIO and DB |
number | constant | 0
|
| SIZE | length of bar (graph) used for ppm display | number | constant | 100
|
| output | description | data type | value type | comment |
| Y | ppm value | number | variable | |
| M | maximum Y | number | variable | |
| P | ppm bar position, always computed for the ppm value in dB (independent of UNIT) | number | variable |
- Description
The level meter value vt (t = sample index) is computed for each value xt of the input signal X. The last vt of an evaluation cycle is used to update the outputs Y and P.
- TYPE=
0orHOLD
- TYPE=
- TYPE=
1orEXPONENTIAL
- TYPE=
- TYPE=
2orRMS
- TYPE=
The computed value v is converted to the selected UNIT and stored in the output Y.
UNIT Y 0orVALUEv 1orSQUAREv2 2orRATIOv / REF 3orDB20 * log10(v / REF)
The output M is the maximum of all computed v values converted to the selected output unit.
The output P is set to a value in range 0 to SIZE and can be used to display a level bar.
The levels -140dB to 0dB are mapped to the values 0 to SIZE using a non-linear mapping function.