Programmer Guide/SPU Reference/PPM: Difference between revisions
From STX Wiki
Jump to navigationJump to search
No edit summary |
No edit summary |
||
Line 51: | Line 51: | ||
|<code>2</code> or <code>RATIO</code> || ''v'' / <var>REF</var> | |<code>2</code> or <code>RATIO</code> || ''v'' / <var>REF</var> | ||
|- | |- | ||
|<code>3</code> or <code>DB</code> | | |<code>3</code> or <code>DB</code> | ||
|<math>20.\log_10(\frac{v_t}{REF})\!</math> | |||
|} | |} | ||
The output <var>P</var> is set to a value in range 0 to <var>SIZE</var> and can be used to display a level bar. For <var>P</var> always the logarithmic value (level in dB) is used. The level interval -140dB to 0dB is mapped to the position interval 0 to <var>SIZE</var> using a non-linear mapping function. | |||
The output <var>M</var> is the maximum of all computed ''v'' values converted to the selected output unit. | The output <var>M</var> is the maximum of all computed ''v'' values converted to the selected output unit. | ||
;See also: | ;See also: | ||
<[[../#Signal Processing Atoms|SP-atoms]]> | <[[../#Signal Processing Atoms|SP-atoms]]> | ||
<!-- AN, 2.5.2011 --> | <!-- AN, 2.5.2011 --> |
Revision as of 09:47, 9 May 2011
Level meter (PPM). This atom is used for the level display in the recorder application.
[SPU PPM X TYPE T UNIT REF SIZE OUT Y M P]
input | description | data type | value type | default value |
---|---|---|---|---|
X | input signal | number, vector | variable | |
TYPE | measurement method ( HOLD, EXPONENTIAL, RMS ) |
number (int.), string | constant | 0 (= HOLD )
|
T | measurement time constant in samples | number | constant | 100
|
UNIT | output value and unit ( VALUE, SQUARE, RATIO, DB ) |
number (int.), string | constant | 0 (=VALUE )
|
REF | reference value, used for UNIT values RATIO and DB |
number | constant | 0
|
SIZE | length of bar (graph) used for ppm display | number | constant | 100
|
output | description | data type | value type | comment |
Y | ppm value | number | variable | |
M | maximum Y | number | variable | |
P | ppm bar position, always computed for the ppm value in dB (independent of UNIT) | number | variable |
- Description
The level meter value vt (t = sample index) is computed for each value xt of the input signal X. The last vt of an evaluation cycle is used to update the outputs Y and P.
TYPE computation of vt 0
orHOLD
1
orEXPONENTIAL
2
orRMS
The last value vt of an evaluation cycle is converted to the selected UNIT and stored in the output Y.
UNIT Y 0
orVALUE
v 1
orSQUARE
v2 2
orRATIO
v / REF 3
orDB
The output P is set to a value in range 0 to SIZE and can be used to display a level bar. For P always the logarithmic value (level in dB) is used. The level interval -140dB to 0dB is mapped to the position interval 0 to SIZE using a non-linear mapping function.
The output M is the maximum of all computed v values converted to the selected output unit.
- See also
<SP-atoms>