MUXOUT

From STX Wiki
Jump to navigationJump to search

MUXOUT - post-processor for output signals

Usage:

MUXOUT SEL L AX AY BX BY PAR SR OUT X Y LX LY PLX PLY

Inputs:
SEL
The X/Y signal selection (number)
L
The frame length (number)
AX, BX
The input signals (vector)
AY, BY
The output signals (vector)
PAR
The processing parameters (vector). See the pre/post processing table notes for details.
SR
The sampling rate in Hz (number)
Outputs:
X,Y
The output signals selected by SEL
LX
The level X (number) in dB
LY
The level Y (number) in dB
PLX
The peak level X (number) in dB
PLY
The peak level Y (number) in dB
Function:

Post-processor, multiplexer, and level-meter for output signals.

Notes:

Post-processing is applied to AY and BY before the selection.

The peak level outputs PLX/PLY are the overall maximum values of PX/PY.

To reset the peak values, use the reset value of the parameter table PAR.

X/Y selection:

SEL X Y Description
0 AX AX mono input A
1 AY AY mono output A
2 AX-AY AX-AY mono difference A
3 AX AY mono input/output a
4 AX AX-AY mono input and difference A
5 BX BX mono input B
6 BY BY mono output B
7 BX-BY BX-BY mono difference B
8 BX BY mono input/output B
9 BX BX-BY mono input and difference B
10 AX BX stereo input
11 AY BY stereo output
12 AX-AY BX-BY stereo difference

Navigation menu

Personal tools