MUXOUT - post-processor for output signals
Usage:
MUXOUT SEL L AX AY BX BY PAR SR OUT X Y LX LY PLX PLY
Inputs:
- SEL
- The X/Y signal selection (number)
- L
- The frame length (number)
- AX, BX
- The input signals (vector)
- AY, BY
- The output signals (vector)
- PAR
- The processing parameters (vector). See the pre/post processing table notes for details.
- SR
- The sampling rate in Hz (number)
Outputs:
- X,Y
- The output signals selected by SEL
- LX
- The level X (number) in dB
- LY
- The level Y (number) in dB
- PLX
- The peak level X (number) in dB
- PLY
- The peak level Y (number) in dB
Function:
Post-processor, multiplexer, and level-meter for output signals.
Notes:
Post-processing is applied to AY and BY before the selection.
The peak level outputs PLX/PLY are the overall maximum values of PX/PY.
To reset the peak values, use the reset value of the parameter table PAR.
X/Y selection:
SEL | X | Y | Description |
0 | AX | AX | mono input A |
1 | AY | AY | mono output A |
2 | AX-AY | AX-AY | mono difference A |
3 | AX | AY | mono input/output a |
4 | AX | AX-AY | mono input and difference A |
5 | BX | BX | mono input B |
6 | BY | BY | mono output B |
7 | BX-BY | BX-BY | mono difference B |
8 | BX | BY | mono input/output B |
9 | BX | BX-BY | mono input and difference B |
10 | AX | BX | stereo input |
11 | AY | BY | stereo output |
12 | AX-AY | BX-BY | stereo difference |